The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. If the pump doesnt come on, follow the steps below. Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. i have an oval pool that is closed for the winter but there ha been a problem. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Turn the power off at the breaker box and carefully remove the wires to the clock. You dont have two OFF trippers, right? I currently manually turn it on and off. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! They should be straight, if not, replace them. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Pool pump comes on fine with the on dog, but wont turn off. Turn the manual on/off switch.
Pool Pump Timer Not Working? Here's Why (+ How to Fix) Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Go for it, a little maintenance expense. If you use our referring links, it costs you nothing extra. Refer to the wiring diagram on the timer door for more information. Once you have confirmed that you timer is working you will need to adjust the timer pins to reflect the time you want your filter system to turn on and off. Hello have a question some what related. Ive got a weak pump battery so every time the mechanism shuts off it looses time. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake.
The 12 Best Pool Timers of 2022 - WildRiver Timer must be reset for current time after power outage. This pool timer is waterproof, heavy-duty, and accurate. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. How about the GFCI outlet TEST button, is it tripped? Wont power on pump but can hear timer clicking away. ft. home is a 3 bed, 4.0 bath property. Video of the Day Trippers "dateModified": "1/10/2020",
Ive reset the time 5 times and just realized that its going counter clockwise. Hi Mike, yes I sent you an email to your yahoo acct. My pool timer is in the off position and it is still running. i would like to use a timer but am now afraid to try another. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. Any other thoughts? Clean the gears with a toothbrush if you see debris or gunk in them. Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). Make sure the middle time pointer is tight. "publisher": {
I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. This will disengage the dial and allow you to spin it in either direction. Theres an issue with the wiring between the circuit breaker and the timer. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Faulty Pump or Wiring from the Timer to the Pump. If its not, then the timer will not turn on/off at the correct times. Also, once it reaches the tripper, the gears in the window no longer move. Thanks in advance! We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. Hello. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on.
Amazon.com: pool timer trippers Your email address will not be published. But of the timer itself is bad you will need a licensed electrician to change the timer for you. It just seems to have a weak start?? "caption": "In The Swim Blog"
I manually turn it on timer is running, it will trip pump OFF. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Phil. Repeat the process for the "on" pin. Watch these tips and tricks before replacing it. For Sale: 2 beds, 2 baths 1152 sq. #1. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. I have a T104. Theres power to the pump using the manual override. If you cant see an issue with the gears, then it could be the timer motor. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. When I turned it back on now the pool clock goes backwards. I took the electrical box cover off and check the breaker connections. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Line is incoming, Load goes to the pump. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. You should be able to see the gears moving. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. The mechanism for the off tripper doesn't work at all when manually depressed.
Intermatic Pool Timer Troubleshooting - In The Swim Pool Blog Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! A timer replacement would be required. Turn in either direction and align the exact time-of-day on . Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side.
The 10 Best Pool Timers - Pool Care Guy One morning I noticed my pool didnt automatically turn off. I have to reset the time every day. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. However, after several hours, maybe overnight, the associated breaker will trip. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. 120Volt Tork 1101 timers can be fixed with repair parts. You should always be able to switch your pump on and off manually at the timer. A timer that switches on and off at the wrong times usually occurs after a power outage. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. Replace them if they appear to be bent. I guess if they look the same as before maybe the dial is warped? Only perform this step if you are qualified. May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Flip off the breaker. Could be small bugs, or dirt, or both causing the problem. Dead as a door nail. Trippers are not installed properly Re-install trippers on dial 2. Some white lithium grease on the switch can help in some cases. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . the problem lies, where the power dies as they say. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Sometimes the trippers get loose or damaged. Set the current time to the center time pointer, pointing downward at 6 oclock. Hi, new timer out of the box, 200V. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Not sure if you still answer these but I have a weird one for you. There is a switch control panel and replaced the 20amps DP switch as well. The position of the metal bar forces the gear next to it to turn one way or another. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. View more property details, sales history and Zestimate data on Zillow. To set it, you just move the on/off "trippers" where you want them.